750 IO module Price List

Model Description Leading Price
Digital Module
In Stock
Subscribe
This digital input module features 16 channels in a width of just 12 mm (0.47 inch).It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity sensors).The module features Push-in CAGE CLAMP® connections enabling solid conductors to be connected by simply pushing them in.Each input channel has a noise-rejection RC filter with 3.0 ms time constant.A green LED indicates the signal state of each channel.Field and system levels are electrically isolated.An operating tool with a 2.5 mm blade (210-719) is required to open the Push-in CAGE CLAMP® connections.
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Number of digital outputs: 16Total number of channels (module): 16Signal type: DigitalSignal type (voltage): 24 VDCActuator connection: 16 x (1-wire)Output characteristics: High-level triggerOutput current per channel: 0.5AOutput current: Short-circuit proofLoad types: Resistive, inductive, lamp loadsMaximum switching frequency: 1 kHzMaximum output data width (internal): 16 bitsSupply voltage (system): 5 VDC; via data contacts
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Number of digital outputs: 8Total number of channels (module): 8Signal type: DigitalSignal type (voltage): 24 VDCActuator connection: 8 x (2-wire)Output characteristics: High-level triggerOutput current per channel: 0.5 AOutput current: Short-circuit proofLoad types: Resistive, inductive, lamp loadMaximum switching frequency: 1 kHzMaximum output data width (internal): 8 bitsSupply voltage (system): 5 VDC; via data contactsCurrent consumption (5 V system power supply): 20 mAField-side supply voltage: 24 VDC (-25 … +30%); via power jumper contacts (power supplied via blade contacts; transmission via spring contacts)Current consumption, field-supplied (module without external load): 15 mA
In Stock
Subscribe
Fieldbus couplers
In Stock
Subscribe
Fieldbus couplers
In Stock
Subscribe
Fieldbus couplers
In Stock
Subscribe
Fieldbus couplers
In Stock
Subscribe
Communication EtherNet/IP™ETHERNET protocol HTTP(S)BootPDHCPDNSFTP(S)SNMPBaud rate 10/100 MbpsTransmission medium (communication/fieldbus) Twisted pair S-UTP 100 Ω Category 5; M12 D-sub, maximum cable length 100 mTransmission performance Class D, in accordance with EN 50173Maximum number of modules per node 64Maximum number of modules without bus extension 64Configuration options WAGO-I/O-CHECKWeb-based managementCODESYS libraryMaximum input and output process image (fieldbus) 1020 words/1020 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP®); derating guidelines must be observed!Current consumption (5 V system power supply): 350 mAMaximum system supply current: 1,700 mAField-side supply voltage: 24 VDC; supplied via pluggable connector (CAGE CLAMP®); transmitted via power jumper contacts; derating guidelines must be observed!
In Stock
Subscribe
Communication: PROFINET IODevice-Specific: Supported protocols: PROFIsafe V2, PROFIenergy V1.0; ID Code: Vendor ID: 0x011D; Device ID: 0x02EE; Module ID: 0x01000177 (firmware versions 01 and 02), 0x02000177 (firmware version 03 and above)PROFINET IO Features: Integrated 2-port switch; Autonegotiation; Auto-MDIX; Isochronous inputs: 1 ms (RT); 1, 2, 4 ms (IRT); Generate/fail programmableBaud rate: 10/100 Mbps (10 Mbps (ETHERNET protocol), 100 Mbps full-duplex communication (PROFINET IO))Maximum bus segment length: 100 mTransmission medium (communication/fieldbus): Twisted-pair S-UTP; 100 Ω; Category 5
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Function and Technology Module
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Wiring ParametersConnection Technology: Inputs/Outputs: 8 x CAGE CLAMP® (inputs)Connectable Conductor Material: CopperConnection Type: InputSolid Conductor: 0.08 … 2.5 mm² / 28 … 14 AWGFine-Stranded Conductor: 0.08 … 2.5 mm² / 28 … 14 AWGStrip Length: 8 … 9 mm / 0.31 … 0.35 inches
In Stock
Subscribe
Number of digital inputs: 4Total number of channels (module): 4Signal type: DigitalSignal type (voltage): 24 VAC/DCSensor connections: 2 x (2-wire, 3-wire); When connecting other sensors, an appropriate field-side wiring module (such as the 750-614) must be used.Input characteristics High level trigger Input filter (digital) 50 ms Typical input current 7.5 mA (AC); 9.5 mA (DC) Signal voltage range (0) −3 … +5 VDC; 0 … 5 VAC Signal voltage range (1) 11 … 30 VDC; 10 … 27 VAC Sensor power supply 24 VAC/DC Maximum input data width (internal) 4 bits Supply voltage (system) 5 VDC; via data contacts Current consumption (5 V system power supply) 10 mA Field side supply voltage 24 VAC/DC (-15 … +20 %); via power jumper contacts (power supply via blade contacts; transmission via spring contacts) Isolation 500 V system/field Indicator LED (A-D) Green: DI 1 … DI 4 status
In Stock
Subscribe
Number of digital inputs: 2Total number of channels (module): 2Signal type: Current loop (intrusion detection)Sensor connection: 2 x (2-wire)Specific sensor properties: Alarm contact: R1 = 1.5 kΩ (±5%); R2 = 2.2 kΩ (±5%); Wire resistance (R-wire): maximum 200 ΩOutput current per channel: 0.001ASensor power supply: 24 VDCMaximum input data width (internal): 4 bitsData width: 4-bit input: 2 bits for data, 2 bits for fault (short circuit/open circuit)Supply voltage (system): 5 VDC; via data contactsCurrent consumption (5 V system power supply): 6 mAField-side supply voltage: 24 VDC (-25 … +30%); via power jumper contacts (power supplied via blade contacts; transmission via spring contacts)Current consumption, field-powered (no external load on module): 16 mAIsolation: 500 V system/field
In Stock
Subscribe
Number of digital input points 2Total number of channels (module) 2Signal type NAMURSensor connection 2 x (2-wire)Input characteristics High level triggerInput filter (digital) 3msSignal current (0) NAMUR ≤1.2mASignal current (1) NAMUR ≥2.1mAOpen circuit voltage 8.2VShort circuit current ≤ 8.2 mASensor power supply 8.2 VDCSwitching hysteresis 0.2mAInput impedance 1,000ΩInput pulse interval ≥3msAnti-mating protection Short circuit monitoring: > 6.5 mAWire break monitoring: < 0.2 mADiagnostics Short circuit, wire breakMaximum input data width (internal) 4BitData width 4-bit input: 2-bit data, 2-bit fault (short circuit/wire break)
In Stock
Subscribe
Number of digital inputs 2Total number of channels (modules) 2Signal type DigitalSignal type (voltage) 110 VDCSensor connection 2 x (2-wire)Input characteristics High/Low level trigger, configurableInput filter (digital) 3msSignal (1) Typical input current per channel 2.5mASignal voltage range (0) −14 … +50 VDCSignal voltage range (1) 70 … 143 VDCSensor power supply 110 VDCMaximum input data width (internal) 2BitSupply voltage (system) 5 VDC; via data contactsCurrent consumption (5 V system power supply) 2.5mAField side supply voltage 110 VDC (-20 … +25 %); via power jumper contacts (power supply via knife contacts; transmission via spring contacts)
In Stock
Subscribe
Digital Module
In Stock
Subscribe
Intrinsically Safe Module (Ex i)
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Number of analog inputs: 4Total number of channels (module): 4Signal type: CurrentSignal type (current): 4 ... 20 mADCSensor connection: 4 x (2-wire)Maximum input voltage: 32 VSignal characteristics: Single-endedResolution: 12 bitsMaximum input impedance: 100 ΩData width: 4 x 16-bit data; 4 x 8-bit control/status (optional)Typical conversion time: 10 msMeasurement error (reference temperature: 25°C)Measurement error, maximum deviation from upper limit: 0.1%
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Analog Module
In Stock
Subscribe
Unsubscribe

Discount Code

Subscribe
Please check the item(s) you are interested in. (required)